What is the clearance for a electrical meter?
Table of Contents
What is the clearance for a electrical meter?
I For safe meter access, a clearance of four feet wide by three feet deep by six feet high is required (see diagram, left). Please keep shrubs, debris, fences and other structures clear of this area. For your safety and ours, do not tamper with the electric meter, its seals or connections.
What is the minimum clearance requirement to maintain sufficient access working space around equipment?
110.32 Work Space About Equipment. Where energized parts are exposed, the minimum clear work space shall be not less than 2.0 m (6 ½ ft) high (measured vertically from the floor or platform) and the width of the equipment or 914 mm (3 ft) wide (measured parallel to the equipment), whichever is greater.
Does 110.26 apply to Transformers?
Question: Is working clearance in accordance with NEC Section 110.26 (A) required for dry type transformers? Answer: No.
What is the minimum space required for a meter?
Electric meters The National Electric Safety Code requires an unobstructed working space that extends from the floor or ground to a minimum height of 6 feet, 6 inches.
What must be provided for in all working spaces above service equipment NEC Section 110.26 D?
Working space illumination is covered in 110.26(D). Illumination shall be provided for all working spaces about service equipment, switchboards, switchgear, panelboards or motor control centers installed indoors.
How far does an electrical panel need to be from water?
The National Electrical Code (NEC) does not specifically address plumbing pipe clearance, but requires an area clear of any obstructions that is 2′-6” wide, 3′-0” deep, and 6′-6” high around the front of a panel [NEC 110.26(A)].
Does a transformer require working clearance?
Generally, a transformer located near a building requires 4ft clearance from the building vertical surfaces, assuming no windows from grade to 18ft.
What is the NEC code for meter height?
While the National Electric Code (NEC) has not specified a minimum, ideal and maximum height for electrical meter boxes, the utility company does. While utility companies may differ, most agree that the center of the meter box should be between four feet and six feet above the ground.
How close can a meter be to a door?
Meters shall not be installed within 36 inches (36″) of a window that has a view of living space or restrooms, or within 36 inches (36″) of a door (guideline). 5.
How Far Can electric panel be from window?
Section 230.9 talks about the 3 ft. min. clearance of open service conductors. But it also says that if the service conductors are in NEC approved conduit, then the conductors ( and the panel as well? ) can be less than 3 feet.
How far can a electrical panel be from the wall?
For example, California’s state building code requires a minimum clearance of 30 inches horizontally in front of an electrical panel. This means you cannot place an electrical panel close to a corner if another wall, fixture or piece of furniture is within 30 inches of it.
Can A breaker Power Panel be in the same utility closet as A water heater?
Based on the letter of the code it is perfectly feasible to have a water heater or sink immediately next to a breaker panel. Contrary to popular belief, an electrical panel, or most other electrical equipment, will not explode and blow up the house if contact with water is made.
Can you run water lines above an electrical panel?
Because there are no other rules governing plumbing pipes around a panel, you can conceivably run them vertically along either side of the panel, but in no case should they interfere with the operation of the panel door or block access to the panel, says Spyrka Electric.