What is PT accuracy class?
Table of Contents
What is PT accuracy class?
The accuracy class is guaranteed if the voltage is between 80 and 120% of the rated primary voltage and for any load between 25 and 100% of the rated accuracy power with an inductive power factor of 0.8. The standardized IEC accuracy classes are: 0.1 – 0.2 – 0.5 – 1 – 3.
What is class of a CT?
CT Class. The standard accuracy classes according IEC are class 0.2, 0.5, 1, 3 and 5. The CT with accuracy class of0.1, 0.2, 0.5, 1.0 accuracy class are used for measurement of electric current.
What is CT accuracy class 0.2 S?
High measuring accuracy The very high 0.2s accuracy class guarantees maximum metering, even with low loads. An 0.2s accuracy class means that the measurement has an error rate of 0.2% over a range of 20 to 120% of the nominal current (In) and at a specific accuracy above 1% of In.
What is PS class CT?
PS Class CT is a special class CT used for differential protection of HT motor,generator and transformer. The PS class CT is also called PX or X type current transformer. The PS class CT should be according to IS2705-part 4.
How is CT accuracy calculated?
In the above-given data, CT is 5P20 with CTR 200/1. The ALF is 20. CT accuracy class is 5. It means if 20 times of the rated primary current(4000 amperes) flows in the primary at the time of fault, the CT reads the current with 5 % accuracy.
What is meant by Class 1 accuracy?
Typically, an active energy meter for a maximum current of 45A, such as the Ulys MD45, is in accuracy class 1: its accuracy will not be worse than 1% in a range extending from 5% In to Imax, or 0.25A to 45A (In = 5A, Imax = 45A).
What is difference between PS and PX class of CT?
PS Class CT is also known as PX Class or simply Class X Current Transformer. It is special type of current transformer meant for protection purpose. Various protection class CTs as described in IS 2705 part-3 is only useful for overcurrent protection. You may refer Accuracy Class of CT for detail.
What is a PS class?
Professional Studies (PS) courses are designed to cultivate and enrich students’ knowledge and skills for and within the workplace.
What is accuracy class in energy meters?
At present, there are four accuracy classes of commonly used electricity meters: 2.0, 1.0, 0.5S and 0.2S, which are usually expressed by A, B, C and D in Europe. Among them, the accuracy class of active electricity meters used by general residential customers is not less than 2.0.
What does the S on the power meter accuracy class 0.2 S & 0.5 s mean?
IEC/AS Standard 62053-22 covers a higher Accuracy Standard of 0.2S and 0.5S for static/electronic for active energy (watt-hours) providing a higher “Accuracy Standard” under full load conditions and unity power factor in addition to better accuracy readings at much lower load currents, power factor conditions less than …
What is accuracy class1?
What is accuracy limit factor of CT?
The accuracy limit factor (ALF) of the CT is defined as the ratio of rated accuracy limit primary current to rated primary current. The protection class CT is marked as 5P10 or 5P20.