What does G mean on a fuse?
Table of Contents
What does G mean on a fuse?
What is a Class G, Fuse? A UL Class G fuse is a 600/480 volts AC current limiting, fuse that is rated to interrupt a minimum of 100,000 amps. Ampere ratings range from ½ amp to 60 amps. The type G fuse meets the NEC, requirements for branch circuit, protection.
What does tt mean on a fuse?
Fuse Markings
Marking | Fuse Element Speed |
---|---|
F | Fast Acting (Flink) |
M | Medium Acting (Mitteltrage) |
T | Slow Acting (Trage) |
TT | Very Slow Acting (Trage Trage) |
What does M205 mean on fuse?
5 x 20mm
The most common sizes are the 5 x 20mm (M205) and the 6.3 x 32mm (3AG) fuses, which account for the greatest volume sales of this group. Originally designed for automotive applications, today they are used in electronics, instrumentation, audio, power supply protection and thousands of different applications.
What does tt mean?
What Does TT Mean? TT stands for “trending topic” in social media, indicating that post is getting many likes and shares.
Are Class K fuses current limiting?
Class K fuses are not permitted to be labeled Current Limiting because there is no rejec- tion feature as required by NEC® Article 240-60(B). INTERRUPTING RATING: 200,000 amps rms symmetrical Not interchangeable with any other UL fuse class.
What is Type K fuse?
The Type K current limiting fuse canister provides an air-insulated receptacle for general-purpose current limiting fuses used on pad-mounted or submersible transformers.
What is a Class K fuse?
Class K fuses. These non-renewable fuses are available in 250VAC and 600VAC ratings, with current ratings from 0A to 600A. Class K fuses are available with DC ratings. The interrupting ratings may be 50kA, 100kA, or 200kA rms symmetrical. Class K-1 fuses provide the best degree of current limitation.
What are H fuses?
What is a Class H, Fuse? A UL Class H fuse is a non-current limiting, fuse that is rated to interrupt a minimum of 10,000 amps. The Class H fuse is a one-time fuse that does not have any appreciable degree of time delay. Class H fuses are rated at either 250 volts AC or 600 volts.
What are Class J fuses used for?
Class J fuses are commonly used in branch circuits, motor circuits, mains, feeders, control panels, electronic motor controllers, drives, soft-starters, circuit breaker back-up, transformers, load centers, lighting, heating and general loads to name a few.
What are J style fuses?
A Class J fuse is a 600 volt AC current limiting, fuse that is rated to interrupt a minimum of 200,000 amps. Bussmann, Littelfuse and Mersen self-certify their Class J fuses to a 300,000 interrupting rating,. Class J fuses are offered in fast acting, or time delay versions.
What is the difference between a Class J and Class R fuse?
All Class R fuses must be labeled “Current Limiting.” They may be labeled “Time Delay,” indicating that they meet the optional time-delay test by not opening in less than 10 seconds at 500% of fuse ampere rating. Class J fuses. These non-renewable fuses are current-limiting and conform to 248-8.