What is an NFPA 13 sprinkler system?
Table of Contents
What is an NFPA 13 sprinkler system?
NFPA 13R is a residential sprinkler design standard focused on low-rise residential occupancies. The Standard’s intent is to provide a sprinkler system that aids in the control of residential fires and provides improved protection against injury and life loss in multi-family dwellings.
Does NFPA 101 require sprinklers?
NFPA 101 requires that all new health care occupancies are provided with automatic sprinkler systems in accordance with NFPA 13, and that smoke compartments containing patient sleeping rooms have quick-response or residential sprinklers used throughout.
What is the major difference between NFPA 13 and NFPA 13D sprinkler systems?
The biggest difference between the three versions of NFPA 13 is the audience they serve and the allowable omissions within 13D and 13R. NFPA 13 and 13D focus mainly on life safety and property protection, while NFPA 13R strictly focuses on the life safety aspect.
What is a Class 4 sprinkler system?
Class IV — This class includes Class I, II, or III products and packaging containing a significant amount of Group A plastics (5-15 percent by weight or 5-25 percent by volume) stored in ordinary corrugated cartons with or without Group A plastic packing, which may be stored with or without the use of pallets.
Where sprinkler system is required?
According to NFPA 13, all newly constructed commercial buildings that are 5,000 square feet or larger are required to have fire sprinkler systems.
When can I use NFPA 13R?
NFPA 13R requires sprinklers in occupied spaces like dwelling units, hallways, and common spaces. It allows places in residential buildings where fatal fires less-commonly start to go without sprinklers, like combustible concealed spaces, small bathrooms, and small closets.
What is the difference between wet and dry sprinkler systems?
Wet vs. Dry Pipe Sprinkler Systems In a wet system, the pipes are filled with pressurized water. When a fire occurs, the system immediately discharges water to extinguish the fire. Conversely, dry systems are filled with pressurized nitrogen or air that keeps water at a riser.
What are the two types of sprinkler systems?
Sprinkler system types
- Wet pipe systems. Wet pipe sprinkler systems are the most common system.
- Dry pipe systems. Dry pipe systems are installed in spaces where the ambient temperature may be cold enough to freeze the water in a wet pipe system, making a wet pipe system inoperable.
- Deluge systems.
- Pre-action systems.
What size water line is needed for fire sprinkler system?
While the most common, traditional domestic service line is size ¾-inch with a ⅝-inch water meter, the most common piping sizes in RFSS applications for one- and two-family dwellings are 1-inch, 1½- inch, and 2-inch.